Product

Home / Product / Detail

VINAGA1-GAMMA COBALT-60 IRRADIATOR

VINAGAMMA-1 Irradiator  was designed and constructed by experienced experts in the fields of operation of industrial scale gamma Co-60 Irradiator  in Vietnam.

VNAGAMMA-1 was desinged and constructed for:

 Sterilization of  medical products: Petri disks, bottles, laboratory apparatus,  surgical gloves, syringes, infusion lines, cottons, dressing, cosmetic products, etc.

Pasteurization of foodstuff:

  Dried seafood  and frozen seafoods,  dried spicse, powder spices, agricultural products and all irradiated fruits for quarantine purposes

Research, development and application in the fields of radiation technology

SPECIFICATIONS

The type of the source: Co-60, or The source: Co-60

C-188/GIK-A6/R2890

Number of source racks and number of  modules in a source racks

3 and 4

Dimention of  tote boxe

50x67x90

Maximum processing speed (minimum irradiation time 80 min)

39 tote boxes/hour

Irradiated productivity according to density

Efficiency of radiation utilization, %

Density: 0.15g/cm3            

20.4± 0.3

Density: 0.45g/cm3

37.5±0.3               

(Dose Uniformity Ratio) –DUR

Value

Density: 0.15g/cm3            

1.40± 0.3

Density: 0.45g/cm3

1.67±0.3

Productivity of irradition (for 500 kCi, d=0.45g/cm3, dose = 3.5 kGy) 2,815 kg/h

Contact

VINAGAMMA-1 Irradiator  was designed and constructed by experienced experts in the fields of operation of industrial scale gamma Co-60 Irradiator  in Vietnam.

VNAGAMMA-1 was desinged and constructed for:

 Sterilization of  medical products: Petri disks, bottles, laboratory apparatus,  surgical gloves, syringes, infusion lines, cottons, dressing, cosmetic products, etc.

Pasteurization of foodstuff:

  Dried seafood  and frozen seafoods,  dried spicse, powder spices, agricultural products and all irradiated fruits for quarantine purposes

Research, development and application in the fields of radiation technology

SPECIFICATIONS

The type of the source: Co-60, or The source: Co-60

C-188/GIK-A6/R2890

Number of source racks and number of  modules in a source racks

3 and 4

Dimention of  tote boxe

50x67x90

Maximum processing speed (minimum irradiation time 80 min)

39 tote boxes/hour

Irradiated productivity according to density

Efficiency of radiation utilization, %

Density: 0.15g/cm3            

20.4± 0.3

Density: 0.45g/cm3

37.5±0.3               

(Dose Uniformity Ratio) –DUR

Value

Density: 0.15g/cm3            

1.40± 0.3

Density: 0.45g/cm3

1.67±0.3

Productivity of irradition (for 500 kCi, d=0.45g/cm3, dose = 3.5 kGy) 2,815 kg/h

other products